@article{Chik-2022-Design,
title = "Design and Validation of Sample Splitting Protocol for Comparison of SARS-CoV-2 Quantification in Wastewater",
author = "Chik, Alex H. S. and
Ho, Jane J. Y. and
Srikanthan, Nivetha and
Dhiyebi, Hadi A. and
Servos, Mark R.",
journal = "Journal of Environmental Engineering, Volume 148, Issue 8",
volume = "148",
number = "8",
year = "2022",
publisher = "American Society of Civil Engineers (ASCE)",
url = "https://gwf-uwaterloo.github.io/gwf-publications/G22-70001",
doi = "10.1061/(asce)ee.1943-7870.0001994",
abstract = "Evaluations of analytical performance through interlaboratory comparisons and proficiency tests are underway globally for biomolecular-based methods [e.g., reverse-transcription quantitative polymerase chain reaction (RT-qPCR)] used in the surveillance of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in wastewater. These evaluations often rely on sharing a common reference wastewater sample that is split among participating laboratories. A known quantity of recovery surrogates can be introduced to the wastewater matrix by the coordinating laboratory as an exogenous control in a spike-and-recovery approach; however, split-sample comparisons are increasingly performed to evaluate in situ quantities of SARS-CoV-2 genetic signal native to the sample due to the lack of a universally accepted recovery surrogate of SARS-CoV-2. A reproducible procedure that minimizes the variability of SARS-CoV-2 genetic signal among split wastewater aliquots is therefore necessary to facilitate the method comparisons, especially when a large number of aliquots are required. Emerging literature has suggested that SARS-CoV-2 genetic signal in wastewater is linked to the solids fraction. Accordingly, a protocol that allows for equal distribution of solids content evenly among wastewater aliquots was also likely to facilitate even distribution of the SARS-CoV-2 genetic signal. Based on this premise, we reviewed existing sample splitting apparatus and approaches used for solids-based parameters in environmental samples. A portable batch reactor was designed, comprised of readily accessible materials and equipment. This design was validated through splitting of real wastewater samples collected from a municipal wastewater treatment facility serving a population with reported cases of COVID-19. This work applies well-established solid-liquid mixing theory and concepts that are likely unfamiliar to molecular microbiologists and laboratory analysts, providing (1) a prototype adaptable for a range of sample quantities, aliquot sizes, microbial targets, and water matrices; and (2) a pragmatic demonstration of critical considerations for design and validation of a reproducible and effective sample splitting protocol.",
}
<?xml version="1.0" encoding="UTF-8"?>
<modsCollection xmlns="http://www.loc.gov/mods/v3">
<mods ID="Chik-2022-Design">
<titleInfo>
<title>Design and Validation of Sample Splitting Protocol for Comparison of SARS-CoV-2 Quantification in Wastewater</title>
</titleInfo>
<name type="personal">
<namePart type="given">Alex</namePart>
<namePart type="given">H</namePart>
<namePart type="given">S</namePart>
<namePart type="family">Chik</namePart>
<role>
<roleTerm authority="marcrelator" type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Jane</namePart>
<namePart type="given">J</namePart>
<namePart type="given">Y</namePart>
<namePart type="family">Ho</namePart>
<role>
<roleTerm authority="marcrelator" type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Nivetha</namePart>
<namePart type="family">Srikanthan</namePart>
<role>
<roleTerm authority="marcrelator" type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Hadi</namePart>
<namePart type="given">A</namePart>
<namePart type="family">Dhiyebi</namePart>
<role>
<roleTerm authority="marcrelator" type="text">author</roleTerm>
</role>
</name>
<name type="personal">
<namePart type="given">Mark</namePart>
<namePart type="given">R</namePart>
<namePart type="family">Servos</namePart>
<role>
<roleTerm authority="marcrelator" type="text">author</roleTerm>
</role>
</name>
<originInfo>
<dateIssued>2022</dateIssued>
</originInfo>
<typeOfResource>text</typeOfResource>
<genre authority="bibutilsgt">journal article</genre>
<relatedItem type="host">
<titleInfo>
<title>Journal of Environmental Engineering, Volume 148, Issue 8</title>
</titleInfo>
<originInfo>
<issuance>continuing</issuance>
<publisher>American Society of Civil Engineers (ASCE)</publisher>
</originInfo>
<genre authority="marcgt">periodical</genre>
<genre authority="bibutilsgt">academic journal</genre>
</relatedItem>
<abstract>Evaluations of analytical performance through interlaboratory comparisons and proficiency tests are underway globally for biomolecular-based methods [e.g., reverse-transcription quantitative polymerase chain reaction (RT-qPCR)] used in the surveillance of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in wastewater. These evaluations often rely on sharing a common reference wastewater sample that is split among participating laboratories. A known quantity of recovery surrogates can be introduced to the wastewater matrix by the coordinating laboratory as an exogenous control in a spike-and-recovery approach; however, split-sample comparisons are increasingly performed to evaluate in situ quantities of SARS-CoV-2 genetic signal native to the sample due to the lack of a universally accepted recovery surrogate of SARS-CoV-2. A reproducible procedure that minimizes the variability of SARS-CoV-2 genetic signal among split wastewater aliquots is therefore necessary to facilitate the method comparisons, especially when a large number of aliquots are required. Emerging literature has suggested that SARS-CoV-2 genetic signal in wastewater is linked to the solids fraction. Accordingly, a protocol that allows for equal distribution of solids content evenly among wastewater aliquots was also likely to facilitate even distribution of the SARS-CoV-2 genetic signal. Based on this premise, we reviewed existing sample splitting apparatus and approaches used for solids-based parameters in environmental samples. A portable batch reactor was designed, comprised of readily accessible materials and equipment. This design was validated through splitting of real wastewater samples collected from a municipal wastewater treatment facility serving a population with reported cases of COVID-19. This work applies well-established solid-liquid mixing theory and concepts that are likely unfamiliar to molecular microbiologists and laboratory analysts, providing (1) a prototype adaptable for a range of sample quantities, aliquot sizes, microbial targets, and water matrices; and (2) a pragmatic demonstration of critical considerations for design and validation of a reproducible and effective sample splitting protocol.</abstract>
<identifier type="citekey">Chik-2022-Design</identifier>
<identifier type="doi">10.1061/(asce)ee.1943-7870.0001994</identifier>
<location>
<url>https://gwf-uwaterloo.github.io/gwf-publications/G22-70001</url>
</location>
<part>
<date>2022</date>
<detail type="volume"><number>148</number></detail>
<detail type="issue"><number>8</number></detail>
</part>
</mods>
</modsCollection>
%0 Journal Article
%T Design and Validation of Sample Splitting Protocol for Comparison of SARS-CoV-2 Quantification in Wastewater
%A Chik, Alex H. S.
%A Ho, Jane J. Y.
%A Srikanthan, Nivetha
%A Dhiyebi, Hadi A.
%A Servos, Mark R.
%J Journal of Environmental Engineering, Volume 148, Issue 8
%D 2022
%V 148
%N 8
%I American Society of Civil Engineers (ASCE)
%F Chik-2022-Design
%X Evaluations of analytical performance through interlaboratory comparisons and proficiency tests are underway globally for biomolecular-based methods [e.g., reverse-transcription quantitative polymerase chain reaction (RT-qPCR)] used in the surveillance of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in wastewater. These evaluations often rely on sharing a common reference wastewater sample that is split among participating laboratories. A known quantity of recovery surrogates can be introduced to the wastewater matrix by the coordinating laboratory as an exogenous control in a spike-and-recovery approach; however, split-sample comparisons are increasingly performed to evaluate in situ quantities of SARS-CoV-2 genetic signal native to the sample due to the lack of a universally accepted recovery surrogate of SARS-CoV-2. A reproducible procedure that minimizes the variability of SARS-CoV-2 genetic signal among split wastewater aliquots is therefore necessary to facilitate the method comparisons, especially when a large number of aliquots are required. Emerging literature has suggested that SARS-CoV-2 genetic signal in wastewater is linked to the solids fraction. Accordingly, a protocol that allows for equal distribution of solids content evenly among wastewater aliquots was also likely to facilitate even distribution of the SARS-CoV-2 genetic signal. Based on this premise, we reviewed existing sample splitting apparatus and approaches used for solids-based parameters in environmental samples. A portable batch reactor was designed, comprised of readily accessible materials and equipment. This design was validated through splitting of real wastewater samples collected from a municipal wastewater treatment facility serving a population with reported cases of COVID-19. This work applies well-established solid-liquid mixing theory and concepts that are likely unfamiliar to molecular microbiologists and laboratory analysts, providing (1) a prototype adaptable for a range of sample quantities, aliquot sizes, microbial targets, and water matrices; and (2) a pragmatic demonstration of critical considerations for design and validation of a reproducible and effective sample splitting protocol.
%R 10.1061/(asce)ee.1943-7870.0001994
%U https://gwf-uwaterloo.github.io/gwf-publications/G22-70001
%U https://doi.org/10.1061/(asce)ee.1943-7870.0001994
Markdown (Informal)
[Design and Validation of Sample Splitting Protocol for Comparison of SARS-CoV-2 Quantification in Wastewater](https://gwf-uwaterloo.github.io/gwf-publications/G22-70001) (Chik et al., GWF 2022)
ACL
- Alex H. S. Chik, Jane J. Y. Ho, Nivetha Srikanthan, Hadi A. Dhiyebi, and Mark R. Servos. 2022. Design and Validation of Sample Splitting Protocol for Comparison of SARS-CoV-2 Quantification in Wastewater. Journal of Environmental Engineering, Volume 148, Issue 8, 148(8).