2023
DOI
bib
abs
Realizing the value in “non-standard” parts of the qPCR standard curve by integrating fundamentals of quantitative microbiology
Philip J. Schmidt,
Nicole Acosta,
Alex H. S. Chik,
Patrick M. D’Aoust,
Robert Delatolla,
Hadi A. Dhiyebi,
Melissa B. Glier,
Casey R.J. Hubert,
Jennifer Kopetzky,
Chand S. Mangat,
Xiaoli Pang,
Shelley Peterson,
Natalie Prystajecky,
Yuanyuan Qiu,
Mark R. Servos,
Monica B. Emelko
Frontiers in Microbiology, Volume 14
The real-time polymerase chain reaction (PCR), commonly known as quantitative PCR (qPCR), is increasingly common in environmental microbiology applications. During the COVID-19 pandemic, qPCR combined with reverse transcription (RT-qPCR) has been used to detect and quantify SARS-CoV-2 in clinical diagnoses and wastewater monitoring of local trends. Estimation of concentrations using qPCR often features a log-linear standard curve model calibrating quantification cycle (Cq) values obtained from underlying fluorescence measurements to standard concentrations. This process works well at high concentrations within a linear dynamic range but has diminishing reliability at low concentrations because it cannot explain "non-standard" data such as Cq values reflecting increasing variability at low concentrations or non-detects that do not yield Cq values at all. Here, fundamental probabilistic modeling concepts from classical quantitative microbiology were integrated into standard curve modeling approaches by reflecting well-understood mechanisms for random error in microbial data. This work showed that data diverging from the log-linear regression model at low concentrations as well as non-detects can be seamlessly integrated into enhanced standard curve analysis. The newly developed model provides improved representation of standard curve data at low concentrations while converging asymptotically upon conventional log-linear regression at high concentrations and adding no fitting parameters. Such modeling facilitates exploration of the effects of various random error mechanisms in experiments generating standard curve data, enables quantification of uncertainty in standard curve parameters, and is an important step toward quantifying uncertainty in qPCR-based concentration estimates. Improving understanding of the random error in qPCR data and standard curve modeling is especially important when low concentrations are of particular interest and inappropriate analysis can unduly affect interpretation, conclusions regarding lab performance, reported concentration estimates, and associated decision-making.
2022
Evaluations of analytical performance through interlaboratory comparisons and proficiency tests are underway globally for biomolecular-based methods [e.g., reverse-transcription quantitative polymerase chain reaction (RT-qPCR)] used in the surveillance of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in wastewater. These evaluations often rely on sharing a common reference wastewater sample that is split among participating laboratories. A known quantity of recovery surrogates can be introduced to the wastewater matrix by the coordinating laboratory as an exogenous control in a spike-and-recovery approach; however, split-sample comparisons are increasingly performed to evaluate in situ quantities of SARS-CoV-2 genetic signal native to the sample due to the lack of a universally accepted recovery surrogate of SARS-CoV-2. A reproducible procedure that minimizes the variability of SARS-CoV-2 genetic signal among split wastewater aliquots is therefore necessary to facilitate the method comparisons, especially when a large number of aliquots are required. Emerging literature has suggested that SARS-CoV-2 genetic signal in wastewater is linked to the solids fraction. Accordingly, a protocol that allows for equal distribution of solids content evenly among wastewater aliquots was also likely to facilitate even distribution of the SARS-CoV-2 genetic signal. Based on this premise, we reviewed existing sample splitting apparatus and approaches used for solids-based parameters in environmental samples. A portable batch reactor was designed, comprised of readily accessible materials and equipment. This design was validated through splitting of real wastewater samples collected from a municipal wastewater treatment facility serving a population with reported cases of COVID-19. This work applies well-established solid-liquid mixing theory and concepts that are likely unfamiliar to molecular microbiologists and laboratory analysts, providing (1) a prototype adaptable for a range of sample quantities, aliquot sizes, microbial targets, and water matrices; and (2) a pragmatic demonstration of critical considerations for design and validation of a reproducible and effective sample splitting protocol.
2021
DOI
bib
abs
Comparison of approaches to quantify SARS-CoV-2 in wastewater using RT-qPCR: Results and implications from a collaborative inter-laboratory study in Canada
Alex H. S. Chik,
Melissa B. Glier,
Mark R. Servos,
Chand S. Mangat,
Xiaoli Pang,
Yuanyuan Qiu,
Patrick M. D’Aoust,
Jean-Baptiste Burnet,
Robert Delatolla,
Sarah Dorner,
Qiudi Geng,
John P. Giesy,
R. Michael L. McKay,
Michael R. Mulvey,
Natalie Prystajecky,
Nivetha Srikanthan,
Yuwei Xie,
Bernadette Conant,
Steve E. Hrudey
Journal of Environmental Sciences, Volume 107
Detection of SARS-CoV-2 RNA in wastewater is a promising tool for informing public health decisions during the COVID-19 pandemic. However, approaches for its analysis by use of reverse transcription quantitative polymerase chain reaction (RT-qPCR) are still far from standardized globally. To characterize inter- and intra-laboratory variability among results when using various methods deployed across Canada, aliquots from a real wastewater sample were spiked with surrogates of SARS-CoV-2 (gamma-radiation inactivated SARS-CoV-2 and human coronavirus strain 229E [HCoV-229E]) at low and high levels then provided "blind" to eight laboratories. Concentration estimates reported by individual laboratories were consistently within a 1.0-log10 range for aliquots of the same spiked condition. All laboratories distinguished between low- and high-spikes for both surrogates. As expected, greater variability was observed in the results amongst laboratories than within individual laboratories, but SARS-CoV-2 RNA concentration estimates for each spiked condition remained mostly within 1.0-log10 ranges. The no-spike wastewater aliquots provided yielded non-detects or trace levels (<20 gene copies/mL) of SARS-CoV-2 RNA. Detections appear linked to methods that included or focused on the solids fraction of the wastewater matrix and might represent in-situ SARS-CoV-2 to the wastewater sample. HCoV-229E RNA was not detected in the no-spike aliquots. Overall, all methods yielded comparable results at the conditions tested. Partitioning behavior of SARS-CoV-2 and spiked surrogates in wastewater should be considered to evaluate method effectiveness. A consistent method and laboratory to explore wastewater SARS-CoV-2 temporal trends for a given system, with appropriate quality control protocols and documented in adequate detail should succeed.