2023
DOI
bib
abs
A comparative analysis of the partitioning behaviour of SARS-CoV-2 RNA in liquid and solid fractions of wastewater
Patrick R. Breadner,
Hadi A. Dhiyebi,
Azar Fattahi,
Nivetha Srikanthan,
Samina Hayat,
Marc G. Aucoin,
Scott Joseph Boegel,
Leslie M. Bragg,
Paul M. Craig,
Yuwei Xie,
John P. Giesy,
Mark R. Servos
Science of The Total Environment, Volume 895
As fragments of SARS-CoV-2 RNA can be quantified and measured temporally in wastewater, surveillance of concentrations of SARS-CoV-2 in wastewater has become a vital resource for tracking the spread of COVID-19 in and among communities. However, the absence of standardized methods has affected the interpretation of data for public health efforts. In particular, analyzing either the liquid or solid fraction has implications for the interpretation of how viral RNA is quantified. Characterizing how SARS-CoV-2 or its RNA fragments partition in wastewater is a central part of understanding fate and behaviour in wastewater. In this study, partitioning of SARS-CoV-2 was investigated by use of centrifugation with varied durations of spin and centrifugal force, polyethylene glycol (PEG) precipitation followed by centrifugation, and ultrafiltration of wastewater. Partitioning of the endogenous pepper mild mottled virus (PMMoV), used to normalize the SARS-CoV-2 signal for fecal load in trend analysis, was also examined. Additionally, two surrogates for coronavirus, human coronavirus 229E and murine hepatitis virus, were analyzed as process controls. Even though SARS-CoV-2 has an affinity for solids, the total RNA copies of SARS-CoV-2 per wastewater sample, after centrifugation (12,000 g, 1.5 h, no brake), were partitioned evenly between the liquid and solid fractions. Centrifugation at greater speeds for longer durations resulted in a shift in partitioning for all viruses toward the solid fraction except for PMMoV, which remained mostly in the liquid fraction. The surrogates more closely reflected the partitioning of SARS-CoV-2 under high centrifugation speed and duration while PMMoV did not. Interestingly, ultrafiltration devices were inconsistent in estimating RNA copies in wastewater, which can influence the interpretation of partitioning. Developing a better understanding of the fate of SARS-CoV-2 in wastewater and creating a foundation of best practices is the key to supporting the current pandemic response and preparing for future potential infectious diseases.
DOI
bib
abs
Assessment of seasonality and normalization techniques for wastewater-based surveillance in Ontario, Canada
Hadi A. Dhiyebi,
Jad Farah,
Heather Ikert,
Nivetha Srikanthan,
Samina Hayat,
Leslie M. Bragg,
Asim Qasim,
Mark Payne,
Linda Kaleis,
Caitlyn Paget,
Dominika Celmer‐Repin,
Arianne M. Folkema,
Sarah Drew,
Robert Delatolla,
John P. Giesy,
Mark R. Servos
Frontiers in Public Health, Volume 11
Introduction Wastewater-based surveillance is at the forefront of monitoring for community prevalence of COVID-19, however, continued uncertainty exists regarding the use of fecal indicators for normalization of the SARS-CoV-2 virus in wastewater. Using three communities in Ontario, sampled from 2021–2023, the seasonality of a viral fecal indicator (pepper mild mottle virus, PMMoV) and the utility of normalization of data to improve correlations with clinical cases was examined. Methods Wastewater samples from Warden, the Humber Air Management Facility (AMF), and Kitchener were analyzed for SARS-CoV-2, PMMoV, and crAssphage. The seasonality of PMMoV and flow rates were examined and compared by Season-Trend-Loess decomposition analysis. The effects of normalization using PMMoV, crAssphage, and flow rates were analyzed by comparing the correlations to clinical cases by episode date (CBED) during 2021. Results Seasonal analysis demonstrated that PMMoV had similar trends at Humber AMF and Kitchener with peaks in January and April 2022 and low concentrations (troughs) in the summer months. Warden had similar trends but was more sporadic between the peaks and troughs for PMMoV concentrations. Flow demonstrated similar trends but was not correlated to PMMoV concentrations at Humber AMF and was very weak at Kitchener ( r = 0.12). Despite the differences among the sewersheds, unnormalized SARS-CoV-2 (raw N1–N2) concentration in wastewater ( n = 99–191) was strongly correlated to the CBED in the communities ( r = 0.620–0.854) during 2021. Additionally, normalization with PMMoV did not improve the correlations at Warden and significantly reduced the correlations at Humber AMF and Kitchener. Flow normalization ( n = 99–191) at Humber AMF and Kitchener and crAssphage normalization ( n = 29–57) correlations at all three sites were not significantly different from raw N1–N2 correlations with CBED. Discussion Differences in seasonal trends in viral biomarkers caused by differences in sewershed characteristics (flow, input, etc.) may play a role in determining how effective normalization may be for improving correlations (or not). This study highlights the importance of assessing the influence of viral fecal indicators on normalized SARS-CoV-2 or other viruses of concern. Fecal indicators used to normalize the target of interest may help or hinder establishing trends with clinical outcomes of interest in wastewater-based surveillance and needs to be considered carefully across seasons and sites.
DOI
bib
abs
Omicron COVID-19 Case Estimates Based on Previous SARS-CoV-2 Wastewater Load, Regional Municipality of Peel, Ontario, Canada
Lydia Cheng,
Hadi A. Dhiyebi,
Monali Varia,
Kyle Atanas,
Nivetha Srikanthan,
Samina Hayat,
Heather Ikert,
Meghan Fuzzen,
Carly Sing-Judge,
Yash Badlani,
Eli Zeeb,
Leslie M. Bragg,
Robert Delatolla,
John P. Giesy,
Elaine Gilliland,
Mark R. Servos
Emerging Infectious Diseases, Volume 29, Issue 8
We determined correlations between SARS-CoV-2 load in untreated water and COVID-19 cases and patient hospitalizations before the Omicron variant (September 2020-November 2021) at 2 wastewater treatment plants in the Regional Municipality of Peel, Ontario, Canada. Using pre-Omicron correlations, we estimated incident COVID-19 cases during Omicron outbreaks (November 2021-June 2022). The strongest correlation between wastewater SARS-CoV-2 load and COVID-19 cases occurred 1 day after sampling (r = 0.911). The strongest correlation between wastewater load and COVID-19 patient hospitalizations occurred 4 days after sampling (r = 0.819). At the peak of the Omicron BA.2 outbreak in April 2022, reported COVID-19 cases were underestimated 19-fold because of changes in clinical testing. Wastewater data provided information for local decision-making and are a useful component of COVID-19 surveillance systems.
DOI
bib
abs
An improved method for determining frequency of multiple variants of SARS-CoV-2 in wastewater using qPCR assays
Meghan Fuzzen,
Nathanael B.J. Harper,
Hadi A. Dhiyebi,
Nivetha Srikanthan,
Samina Hayat,
Leslie M. Bragg,
Shelley Peterson,
Ivy Yang,
Jianxian Sun,
Elizabeth Edwards,
John P. Giesy,
Chand S. Mangat,
Tyson E. Graber,
Robert Delatolla,
Mark R. Servos
Science of The Total Environment, Volume 881
Wastewater-based surveillance has become an effective tool around the globe for indirect monitoring of COVID-19 in communities. Variants of Concern (VOCs) have been detected in wastewater by use of reverse transcription polymerase chain reaction (RT-PCR) or whole genome sequencing (WGS). Rapid, reliable RT-PCR assays continue to be needed to determine the relative frequencies of VOCs and sub-lineages in wastewater-based surveillance programs. The presence of multiple mutations in a single region of the N-gene allowed for the design of a single amplicon, multiple probe assay, that can distinguish among several VOCs in wastewater RNA extracts. This approach which multiplexes probes designed to target mutations associated with specific VOC's along with an intra-amplicon universal probe (non-mutated region) was validated in singleplex and multiplex. The prevalence of each mutation (i.e. VOC) is estimated by comparing the abundance of the targeted mutation with a non-mutated and highly conserved region within the same amplicon. This is advantageous for the accurate and rapid estimation of variant frequencies in wastewater. The N200 assay was applied to monitor frequencies of VOCs in wastewater extracts from several communities in Ontario, Canada in near real time from November 28, 2021 to January 4, 2022. This includes the period of the rapid replacement of the Delta variant with the introduction of the Omicron variant in these Ontario communities in early December 2021. The frequency estimates using this assay were highly reflective of clinical WGS estimates for the same communities. This style of qPCR assay, which simultaneously measures signal from a non-mutated comparator probe and multiple mutation-specific probes contained within a single qPCR amplicon, can be applied to future assay development for rapid and accurate estimations of variant frequencies.
2022
DOI
bib
abs
Multiplex RT-qPCR assay (N200) to detect and estimate prevalence of multiple SARS-CoV-2 Variants of Concern in wastewater
Meghan Fuzzen,
Nathanael B.J. Harper,
Hadi A. Dhiyebi,
Nivetha Srikanthan,
Samina Hayat,
Shelley Peterson,
Ivy Yang,
Jianxian Sun,
Elizabeth A. Edwards,
John P. Giesy,
Chand S. Mangat,
Tyson E. Graber,
Robert Delatolla,
Mark R. Servos
Abstract Wastewater-based surveillance (WBS) has become an effective tool around the globe for indirect monitoring of COVID-19 in communities. Quantities of viral fragments of SARS-CoV-2 in wastewater are related to numbers of clinical cases of COVID-19 reported within the corresponding sewershed. Variants of Concern (VOCs) have been detected in wastewater by use of reverse transcription quantitative polymerase chain reaction (RT-qPCR) or sequencing. A multiplex RT-qPCR assay to detect and estimate the prevalence of multiple VOCs, including Omicron/Alpha, Beta, Gamma, and Delta, in wastewater RNA extracts was developed and validated. The probe-based multiplex assay, named “N200” focuses on amino acids 199-202, a region of the N gene that contains several mutations that are associated with variants of SARS- CoV-2 within a single amplicon. Each of the probes in the N200 assay are specific to the targeted mutations and worked equally well in single- and multi-plex modes. To estimate prevalence of each VOC, the abundance of the targeted mutation was compared with a non- mutated region within the same amplified region. The N200 assay was applied to monitor frequencies of VOCs in wastewater extracts from six sewersheds in Ontario, Canada collected between December 1, 2021, and January 4, 2022. Using the N200 assay, the replacement of the Delta variant along with the introduction and rapid dominance of the Omicron variant were monitored in near real-time, as they occurred nearly simultaneously at all six locations. The N200 assay is robust and efficient for wastewater surveillance can be adopted into VOC monitoring programs or replace more laborious assays currently being used to monitor SARS- CoV-2 and its VOCs.